www.bulgin.co.uk 124 iec connectors ps02/a0311/28 = ps02 series, standard base mounting filter, rated at 3 amperes. l/c circuit version 1, i.e. l1 = 2 x 0.75mh, cx = 15nf, cy = 2 x 2.2nf. with bleed resistor fitted, with 2.8mm tabs. base mounting ps02/a bulkhead mounting ps03/a 1, 3, 6 or 10 amp current rating 3 alternative circuits optional additional components 2.8 or 6.3mm tabs 1, 3, 6 or 10 amp current rating 3 alternative circuits optional additional components 2.8 or 6.3mm tabs specification ps02/axxxx/xx ps03/axxxx/xx part no. example max. working voltage: 250v a.c. 50-400hz 250v a.c. 50-400hz earth leakage current: <0.35ma (250v, 50hz) <0.35ma (250v, 50hz) temperature range: ?5? to +85? ?5? to +85? max. ambient temp.: 40? (derate linearly to 0a @ 85?) 40? (derate linearly to 0a @ 85?) (@ full load) test voltage: 2700v d.c. 2 secs. lines to earth 2700v d.c. 2 secs. lines to earth 1100v d.c. 2 secs. live to neutral 1100v d.c. 2 secs. live to neutral approvals: compliant compliant ps02 or ps03/axx x x /xx additional tag type and series rating l/c circuit components configuration ps02/a 01 = 1a 1 = version 1 0 = none 28 = 2.8mm ps03/a 03 = 3a 2 = version 2 1 = bleed (r) resistor 63 = 6.3mm tabs 06 = 6a 3 = version 3 2 = surge (vdr) protection 10 = 10a 3 = ??plus vdr base mounting and bulkhead base mounting bulkhead mounting mains filters rohs
www.bulgin.co.uk 125 iec connectors rating & version table ps02/axxxx/xx & ps03/axxxx/xx ps02/a011x/xxxx ps03/a011x/xxxx ps02/a012x/xxxx ps03/a012x/xxxx ps02/a013x/xxxx ps03/a013x/xxxx ps02/a031x/xxxx ps03/a031x/xxxx ps02/a032x/xxxx ps03/a032x/xxxx ps02/a033x/xxxx ps03/a033x/xxxx ps02/a061x/xxxx ps03/a061x/xxxx ps02/a062x/xxxx ps03/a062x/xxxx ps02/a063x/xxxx ps03/a063x/xxxx ps02/a101x/xxxx ps03/a101x/xxxx ps02/a103x/xxxx ps03/a103x/xxxx version 1 version 2 version 3 ps02/a102x/xxxx ps03/a102x/xxxx rating version l1 cx cy 1 amp 1 2 x 2.8mh 1 x 15nf 2 x 2.2nf 2 2 x 10mh 1 x 15nf 2 x 2.2nf 3 2 x 10mh 1 x 47nf 2 x 2.2nf 3 amp 1 2 x 0.75mh 1 x 15nf 2 x 2.2nf 2 2 x 1.8mh 1 x 15nf 2 x 2.2nf 3 2 x 1.8mh 1 x 47nf 2 x 2.2nf 6 amp 1 2 x 0.3mh 1 x 15nf 2 x 2.2nf 2 2 x 0.7mh 1 x 15nf 2 x 2.2nf 3 2 x 0.7mh 1 x 47nf 2 x 2.2nf 10 amp 1 2 x 0.17mh 1 x 15nf 2 x 2.2nf 2 2 x 0.35mh 1 x 15nf 2 x 2.2nf 3 2 x 0.17mh 1 x 47nf 2 x 2.2nf mains filters
|